Proper Selection and Use of Vacuum Gauges – Part Two
By Dan Herring
![]() |
| Active Inverted Magnetron Gauge (AIM) |
We continue our discussion of vacuum gauges by focusing on the types of gauges in use throughout the heat treatment industry including their function and application.
Types of Gauges
There are three common types of gauges used in heat treatment, namely mechanical, thermal conductivity, and ionization gauges. Each is unique and well suited for its intended purpose.
Mechanical gauges. The use of mechanical displacement to indicate pressure is considered a type of “direct acting” gauge. Examples are Bourdon gauges, U-tube and capacitance diaphragm manometers. They measure the force per unit area utilizing Dalton’s law: “Total pressure of a mixture of gases equals the sum of the partial pressures of each gas”. Direct acting gauges are not subject to the issue of gas sensitivity and do not need to be calibrated for the gas being measured. Their sensitivity is such that they are not used in the high vacuum range (below ~10-4 mbar).
Thermal Conductivity gauges. These gauges represent a class of “indirect acting” gauges. They use the property of thermal conductivity of gases to measure the pressure. One example is the Pirani gauge, in which a platinum filament is heated, and its heat loss to the vacuum environment is measured. The rate at which heat is conducted away from the wire is directly related to the pressure being measured. At lower pressure and reduced density, the gas in the vacuum chamber conducts the heat away more slowly. At higher pressures the wire will lose its heat more quickly. A second platinum filament, contained in a vacuum tube, is used as a reference. The two filaments are wired in a Wheatstone bridge. When gas molecules in the vacuum system collide with the exposed filament, thermal energy is conducted away, and this loss in thermal energy is detected and replaced by the feedback circuit to the power supply. The amount of electrical current needed to maintain the filament temperature is then converted to a pressure readout. Pirani gauges must be calibrated for the gas being used because the thermal conductivity since each gas is different. This “gas sensitivity” must always be considered when selecting and using indirect acting gauges. This type of gauge is used for pressures between (approximately) 100 Torr and 10−4 Torr. Pirani gauges (Fig. 1) relate the heat lost by the platinum filament to the pressure (Equation 1)3.
(1)
.gif)
Where
Cfil is the heating capacity of the filament,
Mfil is the mass of the filament
C1 and C2 are constants
![]() |
| Figure 14 – Pirani Gauge |
Another type of thermal conductivity gauge is the thermocouple gauge (Fig. 2), which is considered a two-wire gauge. It uses the same principle as the Pirani gauge (a one-wire gauge), except that one wire coil is used as a heater, and the other is used to measure temperature due to convection. Thermocouple gauges and thermistor gauges use a thermocouple or thermistor, respectively, to measure the temperature of the heated wire. Once again, the rate of heat lost by the wire is converted into a pressure and is therefore dependent on the gas constituents of the vacuum range being measured and must be calibrated accordingly.
The convection gauge is also similar to the Pirani gauge, and uses a temperature-compensated, gold-plated tungsten wire to detect the cooling effects of both conduction and convection. At higher vacuum, response depends on the thermal conductivity of the gas, while at lower vacuum it depends on convective cooling by the gas molecules. Measurement range is from 10-3 to 1,000 Torr. With the exception of its wider sensing range, features and limitations of this sensor are the same as those of Pirani and most thermocouple gauges. This sensor must be mounted vertically.
![]() |
| Figure 25 – Thermocouple Gauge |
Pirani, thermocouple and convection gauges are very commonly used in rough and medium vacuum because they are inexpensive and relatively robust. However, the user must remember to apply the gas sensitivity factor, otherwise there can be large errors at the high and low extremes of their measurement range.
These are non-linear gauges and as such the Sgas used has to allow for this (Fig. 3) .
The gas sensitivity of a convection gauge also varies depending on the gas in use (Fig. 4). Here the Y- axis of the graph is actual pressure (measured by a capacitance manometer). The X-axis is the pressure reading indicated by a particular convection gauge. Note this data does not necessarily apply to other convection gauges.
- If the gas is nitrogen (N2), when the true total pressure is 500 Torr, the gauge will read 500 Torr.
- If the gas is argon (Ar), when the true pressure is 100 Torr, the gauge will read approximately 9 Torr.
- If the gas is helium (He), when the true pressure is 10 Torr, the gauge will read approximately 800 Torr.
Ionization Gauges. There are two types of cold-cathode ionization gauges: the Penning gauge and the inverted magnetron. The Penning gauge is the style most often used in vacuum furnaces. Hot cathode ionization gauges can also be used and will be the subject of a future discussion.
Ionization gauges are relatively accurate at high vacuum and are an indirect-acting type of gauge. They sense pressure indirectly by measuring the electrical ions produced when the gas is bombarded with electrons. Fewer ions will be produced by lower density gases. In an ionization gauge, thermionic emission generates electrons, which collide with gas atoms and generate positive ions. The ions are attracted to a suitably biased electrode known as the collector. The current in the collector is proportional to the rate of ionization, which is a directly related to the pressure in the system. By measuring the collector current, the gas pressure is determined. The calibration of an ion gauge is dependent on the properties and proportion of the different gases in the vacuum being measured. Penning gauge calibration is also sensitive to physical geometry, corrosion and surface deposits. Further their calibration can be invalidated by activation at atmospheric pressure or low vacuum.
Cold-cathode gauges such as Penning gauges may not start at very low pressures due to the fact that the near-absence of a gas makes it difficult to establish an electrode current. Penning gauges use an axially symmetric magnetic field to create path lengths for electrons that are of the order of meters. In ambient air, suitable ion pairs are formed by cosmic radiation. In a Penning gauge, design features are used to ease the set-up of a discharge path. For example, the electrode of a Penning gauge is usually finely tapered to facilitate the field emission of electrons.
Maintenance cycles of Penning gauges are, in general, measured in years, depending on the gas type and pressure that they are operated in. Using a cold cathode gauge in gases with substantial organic components, such as pump oil fractions, can result in the growth of delicate carbon films and shards within the gauge that eventually either short circuit the electrodes of the gauge or impede the generation of a discharge path. To help resist against failure due to buildup or debris, these gauges are typically mounted in the vertical down orientation. Penning gauges are accurate in the range of 10-3 to 10-10 Torr.
Where are Vacuum Gauges in a Furnace System and Why?
We now look at the purpose of each specific gauge in a typical vacuum system.
![]() |
| Figure 31 – Relationship of various gases in a Pirani gauge to the true vacuum pressure |
Foreline Gauge
The first step of a vacuum furnace pumping cycle is generally to evacuate the oil diffusion pump to a low enough pressure that the heaters can be switched on. To monitor that pressure, a Pirani, thermocouple or convection gauge is located in the vacuum piping near the exhaust connection of the diffusion pump. This pipeline is called the foreline (of the mechanical pump) or the discharge line (of the diffusion pump). Later in the furnace process cycle, when the diffusion pump is up to operating temperature, the vacuum furnace exits the low vacuum phase and enters high vacuum.
As the crossover is made from roughing to high vacuum pumping, the foreline gauge is used to monitor the diffusion pump discharge pressure. Oil diffusion pumps work with hot oil vapor jets and the discharge pressure must be kept below the critical discharge pressure of the pump and fluid used for the vapor jets to work correctly. The foreline gauge is used to close the high vacuum valve if the discharge line pressure approaches the critical discharge pressure.
Chamber Roughing/Crossover Gauge
The chamber roughing (i.e., crossover) gauge type can be a thermocouple, Pirani or convection style. It is mounted on the vacuum chamber to measure the pressure attained during the low vacuum phase of the process. This is the second step of the evacuation, when the mechanical pumps are directly connected to the chamber through the roughing line.
Once the diffusion pump has heated up and is pumping against the closed vacuum chamber, the foreline valve is closed and the roughing valve opened to allow the mechanical vacuum pump to bring the furnace down to the crossover pressure. In small systems this may take only a few minutes and with clean oil and minimal outgassing the pressure in the discharge line will stay below the critical discharge pressure. For higher volume furnaces, the roughing cycle will take longer. To ensure that the critical discharge pressure is not exceeded while the main mechanical pump is on the roughing cycle, a small 0.14-0.28 m3/min (5 to 10 cfm) mechanical holding pump is included at the discharge side of the diffusion pump to keep the discharge pressure at a safe level.
High Vacuum Gauge
The third gauge, mounted directly on the furnace chamber, is commonly an ionization gauge or capacitance manometer used to measure the high vacuum required for the furnace process cycle. The best location of the vacuum gauge is partly dependent on what is mounted inside the chamber. It would be ideal to know the pressure near the load in the center of the chamber. The gauge head, however, must be mounted on the outside of the chamber and can only measure the vacuum in its own envelope. As a result, it is understood there is a difference between the desired process vacuum and the gauge reading. Therefore the gauge reading determining when vacuum is reached must be determined empirically and is based on experience once this variance is understood.
To minimize this variance, the gauge head should be located as close to where the measurement is needed as possible, which can be a challenge in processes such as vacuum deposition where the gauge interior could be contaminated by the material being evaporated or sputtered. A solution to this is to mount a small line-of-sight shield inside the chamber near the gauge head. Another challenge with Penning gauges is in that they must not be turned on until the pressure is at approximately 10-2 Torr or below. They will be damaged at pressures above 10-2 Torr due to the fact that there is sufficient oxygen present in the chamber to oxidize the gauge head and short it out.
![]() |
| Figure 46 – Difference between measured pressure and actual (true) pressure with different gases, due to gas sensitivity |
Mechanical Vacuum Pump Gauge
A fourth vacuum gauge is mounted near the mechanical vacuum pump inlet on the pump side of an isolation valve. If the vacuum system doesn’t pump down to the expected pressure or in the expected time, the mechanical pump operation must be checked, and this gauge is used for this purpose. This also should be done for the mechanical booster pump if one is mounted above the mechanical pump. It is always helpful to locate a gauge near the pump inlet to allow problem diagnosis and check the pump for proper operation. Over time, the gauge can be contaminated by oil vapor from the mechanical pump. To prevent this, a temporary gauge is installed and removed after use. The system piping is designed with a temporary connection point for the gauge and an isolation valve to shut off the tee when not in use. Portable battery operated gauges are available for this purpose.
Summary
The subject of vacuum gauges is a broad one, and while we have only covered the basics, the implication is clear – to make the most effective use of your pumping systems, you must accurately measure (and control) the pressure at each stage of the process being performed.
References
1. Chew, Andrew, “Calibration Factors for Vacuum Pressure Gauges, Edwards Vacuum LLC, September 2015.
2. Herring, Daniel H., Vacuum Heat Treatment, BNP Media Group, 2012.
3. Patent DE 10115715, Plöchinger, Heinz, “Sensor and Method for Detecting Measurement Variables and Physical Parameters”, 2001 – 2002.
4. University of Alabama (http://bama.ua.edu/~surfspec/vacbasics.htm)
5. National Instruments (www.ni.com)
6. InstruTech, Inc., The Super Bee™ operating manual (www.instrutechinc.com)
7. Brunner Jr., William F. and Batzer, Thomas H., Practical Vacuum Techniques, Robert E. Krieger Publishing Company, 1974.
Daniel H. Herring / Tel: (630) 834-3017) /E-mail: dherring@heat-treat-doctor.com
Dan Herring is president of THE HERRING GROUP Inc., which specializes in consulting services (heat treatment and metallurgy) and technical services (industrial education/training and process/equipment assistance. He is also a research associate professor at the Illinois Institute of Technology/Thermal Processing Technology Center.